en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revisionBoth sides next revision
en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector [2020/03/23 17:53] – [Optionen] Alexandra Thielen:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector [2020/03/24 09:30] – [Lastangaben und Bemessungsfaktoren] Alexandra Thiel
Line 1: Line 1:
-FIXME **This page is not fully translated, yet. Please help completing the translation.**\\ //(remove this paragraph once the translation is finished)//+FIXME **This page is not fully translated, yet. **
  
 ====== Module "SHERPA CLT-Connector" ====== ====== Module "SHERPA CLT-Connector" ======
Line 57: Line 57:
 {{ en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:optionen.png |Options}} {{ en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:optionen.png |Options}}
  
-==== Weitere Systemangaben ====+==== Further system specifications ====
  
-Im Fall des Verbindungstyps "Verbindung Wand-Deckesind Wandhöhe und Wandlänge sowie ein Randabstand anzugebenBei der Wahl des Randabstandes ist immer auf die Montagetauglichkeit zu achten.+In case of connection type "Connection wall-floor", wall height and length as well as an edge distance must be specifiedWhen selecting the edge distance, always pay attention to the mounting suitability.
  
-{{ :clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:weitere_systemangaben.png |Weitere Systemangaben}}+{{ en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:weitere_systemangaben.png |further system specifications}}
  
-==== Lastangaben und Bemessungsfaktoren ====+==== Load data and design factors ====
  
-Je nach gewähltem Verbindungstyp sind entweder Lasten (Verbindungstyp "Verbindung Wand-Decke"oder Schnittgrößen (Verbindungstyp "Eckverbindungund "Verbindung in der Ebene"einzugeben.+Depending on the selected connection type, either loads (connection type "connection wall-floor"or internal forces (connection type "corner connectionand "connection in-plane"must be specified.
  
-**Verbindungstyp "Verbindung Wand-Decke"**+**Connection type "connection wall-floor"**
  
-Beim Verbindungstyp "Verbindung Wand-Deckekönnen eine horizontale und eine vertikale Last (Bemessungswertangegeben werdenDie benötigte Anzahl der Verbinder sowie die jeweiligen Kräfte auf die einzelnen Verbinder werden unter Einbeziehung der Geometrie und der Randabstände sowie der minimalen und maximalen Abstände untereinander mittels eines [[https://www.holzbauforschung.at/fileadmin/user_upload_CLTdesigner/Download/ExcerptDissFlatscher_GarvicEtAl2015a.pdf|linear elastischen Federmodells]] berechnet.+For the connection type "connection wall-floor", a horizontal and a vertical load (design valuecan be specifiedThe required number of connectors as well as the respective forces on the individual connectors are calculated by means of a [[https://www.holzbauforschung.at/fileadmin/user_upload_CLTdesigner/Download/ExcerptDissFlatscher_GarvicEtAl2015a.pdf|linear elastic spring model]], taking into account the geometry and the edge distances as well as the minimum and maximum distances between them.
  
-{{ :clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:lasten.png |Lastangaben}}+{{ en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:lasten.png |Load data}}
  
-**Verbindungstyp "Eckverbindungund "Verbindung in der Ebene"**+**Connection type "corner connectionand "Connection in-plane"**
  
-Bei den Verbindungstypen "Eckverbindungund "Verbindung in der Ebeneerfolgt die Angabe der Beanspruchung über Schnittgrößen (wirkende Kräfte auf den betrachteten Verbinder). Der Verbinder kann durch eine Normalkraft sowie durch Querkräfte in und aus der Ebene beansprucht werdenBei den anzugebenden Schnittgrößen handelt es ich um BemessungswerteAuf die korrekte Eingabe des Vorzeichens ist zu achten.+For the connection types "corner connectionand "connection in-plane", the action is specified by internal forces (forces acting on each individual connector). The connector can be exposed to a normal force as well as to shear forces in and out of planeThe internal forces to be specified are design valuesMake sure that the sign is entered correctly.
  
-{{ :clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:schnittgroessen.png |Schnittgrößen}}+{{ en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:schnittgroessen.png |Internal forces}}
  
-Des Weiteren sind der Modifikationsbeiwert k<sub>mod</sub> und der Teilsicherheitsbeiwert γ<sub>M</sub> anzugeben.+Furthermore, the modification coefficient k<sub>mod</sub> and the partial safety factor γ<sub>M</sub> must be specified.
    
-{{ :clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:bemessungsfaktoren.png |Bemessungsfaktoren}}+{{ en:clt:hotspot:software:cltdesigner:manual:modul_sherpa_clt_connector:bemessungsfaktoren.png |Design factors}}
  
 ===== Ergebnisse und Ausgabe ===== ===== Ergebnisse und Ausgabe =====
  • en/clt/hotspot/software/cltdesigner/manual/modul_sherpa_clt_connector.txt
  • Last modified: 2020/10/28 10:15
  • by Alexandra Thiel