In addition to plate dimensions, the analysis also considers the way the lamellas are joined into individual layers. Regarding to the joining of the outer layers, one should differ:
In addition to plate dimensions, the analysis also considers the way the lamellas are joined into individual layers. Regarding to the joining of the outer layers, one should differ:
* side gluing of lamellas,
* side gluing of lamellas,
-
* assembly without adhesive where lamellas are placed side by side without the sheduled gaps or the expected occurence of cracks and
+
* assembly without adhesive where lamellas are placed side by side without the scheduled gaps or the expected occurrence of cracks and
-
* possible occurence of gaps or cracks wider than 1 mm.
+
* possible occurrence of gaps or cracks wider than 1 mm.
==== Load data and design factors ====
==== Load data and design factors ====
Line 47:
Line 45:
==== Calculation options ====
==== Calculation options ====
-
In den Berechnungsoptionen können die Lastausbreitungswinkel für Längslagen α<sub>0</sub> und für Querlagen α<sub>90</sub> verändert werden sowie bei einseitiger Lasteinleitung kann angegeben werden, in welcher Höhe (= k<sub>ls</sub> ⋅ t<sub>CLT</sub>) die effektive Fläche bestimmt werden soll.
+
In the calculation options, the load distribution angles for longitudinal layers α<sub>0</sub> and cross layers α<sub>90</sub> can be changed, and for one-sided load introduction, it can be specified, in which depth (= k<sub>ls</sub> ⋅ t<sub>CLT</sub>) the effective area is to be determined.
Die minimale Lasteinleitungsfläche beschreibt die Bezugsfläche, um mit dem Querdruckbeiwert k<sub>c,90</sub> auf die effektive Fläche A<sub>ef,max</sub> zu kommen. Bei unterschiedlichen Beanspruchungsflächen oben und unten ist es die Überschneidungsfläche der beiden Beanspruchungsflächen. Die effektive Fläche A<sub>ef,max</sub> wird durch l<sub>ef</sub> und w<sub>ef</sub> in der Höhe z beschrieben.
+
The minimum load introduction area A<sub>c,min</sub> describes the reference area in order to get the effective area A<sub>ef,max</sub> by multiplying with the factor k<sub>c,90</sub>. For different load introduction areas on each side it is the intersection of these two areas. The effective area A<sub>ef,max</sub> is described by l<sub>ef</sub> and w<sub>ef</sub> in depth z.
-
Die Ausnutzung auf Querdruck wird durch den Ausnutzungsgrad η<sub>c,90</sub> in [%] angegeben.
+
The utilisation ratio for compression perpendicular to grain is indicated by η<sub>c,90</sub> in [%].
{{ en:clt:hotspot:software:cltdesigner:manual:modul_compression_perpendicular_to_grain:ergebnisse.png |Results compression perpendicular to grain}}
{{ en:clt:hotspot:software:cltdesigner:manual:modul_compression_perpendicular_to_grain:ergebnisse.png |Results compression perpendicular to grain}}
-
In der folgenden Skizze wird der Verlauf der effektiven Fläche A<sub>ef,max</sub> über die Querschnittshöhe (rote Linie) sowie der Verlauf der angenommenen Lastausbreitung (blaue Linie) angezeigt.
+
The following figure shows the distribution of the effective area A<sub>ef,max</sub> over the cross section (red line) as well as the assumed load distribution (blue line).