The input is divided into:
Currently the following connection types are available:
corner connection | connection in-plane | connection wall-floor |
---|
The elements to be connected are defined by the respective layup. The input is the same as for the Module "CLT-Plate 1D - Continuous beam".
If milling is necessary due to the thickness of the elements, a warning message is displayed and, if possible, an alternative screw length is mentioned.
The SHERPA CLT-Connector is fixed on element 1 (base element) at the factory by using 6 SHERPA special screws. A further 4 SHERPA special screws are used to connect element 2 (element to be connected). The length of the inclined screws can be 100 mm, 120 mm or 140 mm, depending on requirements.
Intermediate layers such as compriband or sound insulation layers can be placed between the elements. Since the installation of a sound insulation layer influences the load capacity "shear force out of plane", this must be indicated via the option "sound insulation layer ≤ 12 mm".
In case of connection type "Connection wall-floor", wall height and length as well as an edge distance must be specified. When selecting the edge distance, always pay attention to the mounting suitability.
Depending on the selected connection type, either loads (connection type "connection wall-floor") or internal forces (connection type "corner connection" and "connection in-plane") must be specified.
Connection type "connection wall-floor"
For the connection type "connection wall-floor", a horizontal and a vertical load (design value) can be specified. The required number of connectors as well as the respective forces on the individual connectors are calculated by means of a linear elastic spring model, taking into account the geometry and the edge distances as well as the minimum and maximum distances between them.
Connection type "corner connection" and "Connection in-plane"
For the connection types "corner connection" and "connection in-plane", the action is specified by internal forces (forces acting on each individual connector). The connector can be exposed to a normal force as well as to shear forces in and out of plane. The internal forces to be specified are design values. Make sure that the sign is entered correctly.
Furthermore, the modification coefficient kmod and the partial safety factor γM must be specified.
Information about the CLT-Connector is displayed between the input data (left) and the graphic (right). This includes, on the one hand, the load capacities and stiffnesses depending on the direction of loading and, on the other hand, the basis of the calculation (ETA, data specification and computation model).
As a result, the utilisation ratios of the respective stress as well as the combined stress are indicated. The output differs slightly depending on the selected connection type.
Connection type "connection wall-floor"
For this connection type, the maximum utilization ratios as well as the utilization ratio of each individual connector are specified.
Connection type "corner connection" and "connection in-plane"
In addition to the utilization ratios, any warnings, e.g. regarding suitability for mounting and eccentricity of the connection, are also displayed here.
And to pay special attention:
The CLT elements must be verified separately!